Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Small Scale Medical Waste Incinerators
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ | 800℃–1000℃ |
2nd. Chamber Temperature | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ | 1000℃-1200℃ |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Waste Incinerators International Market Analytics
Key Word:
small incinerators
medical waste incinerator
pet animal cremation incinerator
incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be named many words as below:
Treatment capacity: small scale incinerator, large scale incinerator and incineration pant.
Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators
Incinerator fuel: gas incinerator, oil incinerator
Waste to Energy (WTE): WTE incinerator, non-WTE incinerator
Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer.
Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA) , Haat (India)
Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a social problem, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.
So, why we still use incinerator?
First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution control.
Second, for human body, pet animal, in many countries and regions, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
How you can find reasonable incinerator for your local site?
Incinerator is not a cheap equipment, generally the small scale model’s price around $5,000usd per unit and large scale model’s price more than $50,000usd per unit. So, before purchase one unit incinerator, you have to make clear following items:
A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment?
B, small or large? This according to the waste output every day or the waste volume per feed time, like animal size.
C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don’t have gas supply system.
And other technology items, like power(220v, 380v), waste feed door type, incinerator structure, etc.
After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and ultimately purchasing the right products.
Pet Animal Crematory
Clover Incinerator update A model incinerator for pet cremation and animal incineration. New design accept independent movable platform in-out incinerator combustion chamber. This new design is valid for model A900 and bigger model.
multiple diesel fuel combustion incinerators
The incinerators to be supplied shall meet the following specifications
- ISO certified
- Model: 250LA ,multiple diesel fuel combustion chambers
- Performance capacity
- 120Kg/hr GRE 1.25 for HCRW
- 96Kg/hr GRE 1.25 for general waste.
- 40Kg/hr GRE 3.00 for plastic
- Waste type : health care risk waste and general waste
- Chimney stack:
- Chimney : 3.5mm mild steel
- Height from base :11m and if there are buildings within
30m of the incinerator, chimney must extend at least 3m
above the apexes of all the roof of such buildings
- Diameter of chimney at top :430mm
- Weight of stack: ±500 Kg
- Case and stack be painted with 400⁰C heat resistant Black paint
- Burners:
- 1st chamber 850⁰C – 900⁰C
- 2nd chamber 1000⁰C
- Variable speed combustion air blowers
- Primary chamber volume ±1.05 cubic metres
- Mixing chamber volume ±0.30 cubic metres
- Settling chamber volume ±0.89 cubic metres
- Weight excluding chimney ±6.400Kg at manufacture
- .Firing tools supplied :Hoe ,poker and rake
- Dimensions
- Length ±2125mm
- Width ±1890mm
- Height ±2125mm
- Extra width for burners ± 1000mm
- Loading door opening 610 *540mm
- Hearth area ±1.19square metres
- Description of grate/hearth :A full hearth to be supplied to prevent contaminated
- Liquids from flowing into ash pit without being incinerated
- Compliance with South African Atmospheric Pollution Prevention Act No.45 of
1965 or equivalent air pollution standards
- Documents to be supplied :Operations and maintenance manual and standard
operating procedures (SOPs)
- Emission controls:
- heated refractory screen
- Low velocity grit settling chamber
- Stainless steel arrester screen
- Refractory material :alumina content> 49% and thickness average 102mm
- Bake out : to be done over 2-3 days
- Materials of constructions
- Case :5mm mild steel
- Bracing: heavy angle and channel
- Hearth: 1550 ⁰C
- Ashing door: high grade cast iron
- Loading door 5mm mild steel lined with 1550 ⁰C castable general purpose high strength, high abrasion resistant monolithic refractory concrete.
- Incinerator walls and roof: 1550 ⁰C castable monolithic refractory
- Temperature: ≥ 90 ⁰C
- Insulation to walls: 1000 ⁰C castable insulation
- Electricity supply required: 220volt, 15amp single phase
- Controls:
- Draught control: barometer indicator, door operated draught limiter
- Air supply: built-in forced heated air ducts, primary and secondary (intensifier)
- Electric: control panel includes-circuit breakers, main switch, timer, pilot lights, 2 set point pyrometer and one set point pyrometer
Summary of Key Expected Activities/Outputs
- Replacement of pipes from the tank to the incinerator
- Covering pipes to protect them bursting in winter
- Replacement of gauge
- Incinerator installation
- Installation report
- End of contract report
Incinerator Questions
Technological University of Panama: an environmental research about the municipal waste in Panama city. I found some incinerators from Clover Incinerator and I think they are perfect for my research but I have a question and it is if the incinerator can have a waste sluice additional to it?
University of Bologna:We are designing a bioreactor for human waste; the digestate is useless for fertiizing the soil. The only solution for digestate disposal is burning it. Throught your on-line page, we saw the Model: SYC-50 Incinerator that could be perfect for our trouble. The question is: natual gas, like biogas is a correct fuel? And what is the right quantity of fuel necessary for burning?