Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Small-Scale Medical Waste Incinerators in Togo
Small-Scale Medical Waste Incinerators in Togo
Togo, a small West African nation, is experiencing steady development in its healthcare sector, with growing awareness about safe medical waste disposal. Clinics, regional hospitals, and rural health posts are increasingly seeking affordable, efficient solutions for disposing of infectious waste, used syringes, contaminated dressings, and expired pharmaceuticals.
Among the solutions, small-capacity medical waste incinerators like the HICLOVER TS10, TS20, and TS30 series have found practical and effective applications. Let’s explore why these systems are being chosen and what makes them suitable for Togo’s healthcare facilities.
Current Situation of Medical Waste in Togo
In Togo, most medical waste is generated by:
-
Regional hospitals in cities like Lomé, Sokodé, Kara, and Atakpamé
-
Private clinics and small maternity wards
-
Health posts spread across rural areas
Traditionally, open burning or shallow burial was common practice—methods that pose serious risks of groundwater contamination, air pollution, and disease transmission. Recent initiatives supported by international NGOs, the Ministry of Health, and development agencies have encouraged healthcare facilities to invest in compact, controlled incineration units.
Why Small-Scale Incinerators Work Well in Togo
Togo’s healthcare infrastructure is largely decentralized:
-
Many rural centers handle 5–30 kg of infectious waste daily.
-
Electricity supply can be inconsistent, and facilities need easy-to-operate, low-maintenance solutions.
-
Regulations are becoming stricter, requiring proper waste treatment that meets WHO recommendations.
Small-capacity incinerators (like HICLOVER TS10, TS20, TS30) perfectly match these needs:
-
Affordable purchase and operating costs
-
Low fuel consumption
-
Compact size suitable for small plots
-
Reliable performance, even under challenging conditions
The HICLOVER TS10, TS20, TS30 Series: Key Features
Burn Rate & Capacity:
-
TS10: ~10 kg/hour
-
TS20: ~20 kg/hour
-
TS30: ~30 kg/hour
-
Feed capacity designed for small daily loads
Robust Construction:
-
Chambers lined with high alumina refractory bricks
-
Durable steel casing protected by high-temperature paint
Smart & Safe:
-
PLC-based automatic operation (TS30 optional)
-
Corundum probe thermometers rated up to 1600°C
-
Flame observation windows
-
Optional dual fuel capability (Diesel & LPG/Natural Gas)
Efficiency & Control:
-
Two combustion chambers: primary and secondary
-
Secondary chamber designed to sustain temperatures above 1000°C
-
Retention time ≥ 2 seconds for complete combustion of harmful gases
Wet Scrubber Dust Removal System: A Cleaner Solution
To meet environmental standards and improve air quality:
-
HICLOVER offers optional wet scrubbers to remove particulates, acid gases, and dioxin precursors.
-
This makes the incinerators suitable for facilities near residential areas, schools, or markets.
Benefits:
-
Reduces visible smoke and odor
-
Lowers emissions of hazardous compounds
-
Compact design that integrates with containerized or trailer-mounted systems
Practical Applications in Togo
Small-capacity incinerators are used in:
-
Regional hospitals in Lomé and Kara
-
NGO-run rural clinics
-
Maternity centers dealing with placenta waste and sharps
-
Veterinary clinics treating animal waste
These units have helped facilities:
-
Stop unsafe open burning practices
-
Comply with local environmental and health regulations
-
Protect staff, patients, and nearby communities
Why Choose HICLOVER?
HICLOVER, known for its range of medical and general waste incinerators, stands out by:
-
Delivering CE-certified, ISO9001:2015-certified products
-
Offering containerized and trailer-mounted solutions
-
Providing customized capacity and fuel type options
-
Supplying replacement spare parts and burner support
-
Global export experience, including over 50 countries (e.g., Kenya, Nigeria, Cameroon, Rwanda, Afghanistan, Somalia, Mauritius, Papua New Guinea, etc.)
Contact & Learn More
For clinics, health posts, and NGOs in Togo looking for efficient, small-scale medical waste treatment:
Contact HICLOVER today
Website: www.hiclover.com
Email: sales@hiclover.com
Discover how the TS10, TS20, TS30 series with optional wet scrubber systems can help you safely, efficiently, and affordably manage medical waste.
HICLOVER Containerized Incinerators for Biohazard Waste Treatment
HICLOVER Containerized Incinerators for Biohazard Waste Treatment
As part of its mandate to improve health and environmental safety, UNOPS is sourcing two high-capacity, containerized biohazard waste incinerators for its operations in South Sudan. These units must enable the safe on‑site destruction of biological samples and materials that pose risks to human health and the environment. HICLOVER’s TS200 and TS300 models are ideally suited to meet these requirements.
Why HICLOVER Incinerators Are the Right Choice
-
Containerized, Plug‑and‑Play Design
• Delivered in a single ISO container for rapid deployment
• No permanent foundation required—ideal for remote or emergency field sites
• Secure, weather‑resistant steel enclosure protects internal systems -
Top‑Loading Combustion Chamber
• Large top‑loading door simplifies batch feeding of bulky biohazard waste
• Reduces operator exposure and speeds up loading cycles
• Optional front or side feeding doors available for site‑specific workflows -
Reliable PLC‑Automatic Control
• Fully automated temperature and combustion control via 3.7″ LCD interface
• Intelligent sensors maintain high‐temperature retention (HTR) and adjust fuel use
• Automatic false‑alarm detection and system testing ensure continuous operation -
High‑Temperature Dual‑Chamber Combustion
• Primary chamber reaches 800–1,000 °C; secondary chamber maintains 1,000–1,300 °C for a 2‑second residence time
• Eliminates bacteria, viruses, and prions in pathological waste, sharps, and animal by‑products
• Refractory‑lined chambers (1750 °C grade, ≥115 mm thickness) guarantee durability under heavy use -
Fuel Flexibility and Efficiency
• Standard diesel burner (Italy brand) with optional natural gas support
• Intelligent fuel‑saving mode reduces operating costs during low‑load periods
• TS200 consumes approximately 22 kg of oil per hour; TS300 consumes 28 kg per hour -
Environmental Compliance and Safety
• Stainless‑steel chimney (8 m height) or refractory‑lined stack (1 m) ensures proper dispersion of flue gases
• Optional wet scrubber and particulate filter modules available to meet strict local or donor‑mandated emission standards
• Fully sealed loading and ash‐removal doors contain odors and prevent fugitive emissions
Model Specifications
HICLOVER TS200 (PLC‑Automatic)
-
Average Burn Rate: 180 kg/hour
-
Feed Capacity: 200–250 kg per batch
-
Primary Chamber Volume: 1.98 m³ (1,980 L)
-
Secondary Chamber Volume: 0.8 m³ (800 L)
-
Internal Dimensions: 1,650 × 1,200 × 1,000 mm
-
Power Supply: 220 V (2 kW; 8 kW if scrubber installed)
-
Fuel Consumption: Diesel 22 kg/hour or natural gas 25 m³ n/hour
-
Control: PLC with 3.7″ LCD, corundum probe (1,600 °C rating), automatic cooling, alarm systems
-
Oil Tank: 400 L with level display
-
Gross Weight: 8,000 kg
-
External Dimensions: 3,800 × 1,700 × 1,600 mm (excluding chimney)
HICLOVER TS300 (PLC‑Automatic)
-
Average Burn Rate: 220 kg/hour
-
Feed Capacity: 250–350 kg per batch
-
Primary Chamber Volume: 2.4 m³ (2,400 L)
-
Secondary Chamber Volume: 1.0 m³ (1,000 L)
-
Internal Dimensions: 2,000 × 1,200 × 1,000 mm
-
Power Supply: 220 V (2 kW; 8 kW if scrubber installed)
-
Fuel Consumption: Diesel 28 kg/hour or natural gas 32 m³ n/hour
-
Control: PLC with 3.7″ LCD, corundum probe, automatic cooling, alarm systems
-
Oil Tank: 400 L with level display
-
Gross Weight: 10,000 kg
-
External Dimensions: 4,200 × 1,700 × 1,600 mm (excluding chimney)
Both models carry CE and ISO 9001:2015 certification and offer optional features such as pre‑heat fuel saving, dual‑fuel capability, automatic ash removal, and mobile container/trailer mounting.
Meeting UNOPS Objectives
By selecting HICLOVER TS200 or TS300 incinerators, UNOPS South Sudan will benefit from:
-
On‑site biohazard destruction aligned with WHO and UN environmental health guidelines
-
Rapid deployment with minimal civil works and commissioning time
-
Operator safety through intelligent controls and top‑loading design
-
Long‑term reliability supported by durable refractory materials and global spare‑parts availability
-
Reduced lifecycle costs via fuel‑saving functions and PLC‑optimized combustion
For further information, detailed technical data sheets, or shipping arrangements to South Sudan, please contact HICLOVER at sales@hiclover.com or visit www.hiclover.com.
Choose HICLOVER for proven, high‑performance biohazard waste incinerators that safeguard health and protect the environment.
HICLOVER TS200 PLC Incinerator: Advanced Waste Disposal Solution Tailored for South Sudan
HICLOVER TS200 PLC Incinerator: Advanced Waste Disposal Solution Tailored for South Sudan
In recent years, South Sudan has faced increasing pressure to improve its waste management, particularly for medical waste, humanitarian camp waste, and other high-density refuse. The HICLOVER TS200 PLC incinerator is an industrial-grade solution engineered to meet exactly these challenges, combining advanced technology, reliability, and local adaptability.
This article highlights how the HICLOVER TS200 PLC aligns perfectly with South Sudan’s unique needs, its key technical specifications, and why it is the smart choice for hospitals, refugee camps, NGOs, and governmental projects.
Designed for Heavy-Duty Operation in Demanding Environments
The HICLOVER TS200 PLC is built for a burn rate of around 180 kg/hour, supported by a large primary combustion chamber of 1.98 m³ and a secondary chamber of 0.8 m³. This large capacity ensures it can handle high daily waste volumes typical of large hospitals, refugee camps, and urban waste centers.
Its manual feed mode combined with a top-loading door (1300x1000mm) allows operators to load large quantities (average 200–250 kg per feeding) safely and efficiently. This design works well even when electrical infrastructure is unstable—a common issue in South Sudan.
PLC Automatic Control & Intelligent Safety Features
At the heart of this model lies a fully automated PLC control system, featuring:
-
Temperature monitoring with a corundum probe (rated up to 1600°C).
-
Automatic high-temperature retention: keeps 1st chamber at 800–1000°C and 2nd chamber at 1000–1300°C.
-
Automatic fuel-saving mode.
-
Automatic cooling and false alarm systems with display, voice, and light alerts.
-
3.7-inch LCD screen for real-time status updates.
-
System testing mode & time setting to support routine safety checks.
These intelligent functions protect operators, improve burn efficiency, and reduce fuel consumption—essential for remote areas where diesel or LPG supply can be limited or costly.
Engineered for Local Needs in South Sudan
Fuel Flexibility:
-
Uses diesel (avg. 22 kg/hour) or natural gas (approx. 25 m³n/hour).
-
Comes with a 400L oil tank and liquid level display for easy onsite fuel management.
Robust Construction:
-
Refractory lined chimney (1 meter) and stainless steel chimney (8 meters), ideal for withstanding harsh outdoor conditions.
-
Hot face of the combustion chambers is lined with high alumina refractory bricks (≥115 mm thickness, 65% Al₂O₃, 1750°C grade).
-
Cold face lined with high-rate refractory ceramic fiber for insulation.
Protection & Maintenance:
-
Automatic on/off Italy brand burners reduce manual intervention.
-
Sealing materials are heat-resistant ceramic fiber, ensuring minimal heat loss and maximum safety.
-
External paint rated for 250°C protects the steel body from rust and weather.
Compact & Upgradeable Design
The TS200 PLC’s design makes it highly adaptable:
-
External dimensions: 3800x1700x1600mm (without chimney).
-
Gross weight: ~8000 kg—heavy-duty yet still movable using flatbeds or cranes.
-
Containerized mobile option: For field hospitals, UN camps, or mining sites.
-
Wet scrubber (optional): For reducing flue gas pollutants and meeting stricter environmental standards.
-
Front or side loading doors (optional): To suit different waste logistics setups.
Certifications & Compliance
The HICLOVER TS200 PLC is fully certified:
-
CE certificates: CE(2006/42/EC, 2014/30/EU).
-
ISO9001:2015 certified manufacturing.
-
Recognized as a High-tech Enterprise.
This ensures it meets international safety, quality, and environmental compliance—a critical factor for projects supported by global NGOs, UN agencies, and international donors.
Practical Efficiency & Local Suitability
Residency time of 2 seconds in the secondary chamber ensures full combustion, minimizing harmful emissions—important for environmental health in populated camps or hospitals.
Temperature protection and automatic shutdown features protect the system and staff against overheating and mechanical faults—vital in regions with limited technical support.
Its combination of large capacity, automatic control, intelligent fuel saving, and safety features offers a low running cost per ton of waste, making it sustainable even in South Sudan’s challenging economic context.
Environmental Commitment
Optional wet scrubbers help reduce emissions further, aligning with rising international environmental standards and local air quality goals.
The high combustion temperature range (up to 1300°C) ensures complete destruction of pathogens in medical waste—critical for public health.
Why Choose HICLOVER TS200 PLC for South Sudan?
-
High capacity for large hospitals & camps.
-
Automatic PLC control minimizes skilled labor dependency.
-
Fuel-saving intelligent mode lowers operational costs.
-
Designed to handle unstable electricity & fuel supply.
-
CE & ISO certified—ready for donor-funded or NGO projects.
-
Containerized and mobile options to reach remote areas.
Contact HICLOVER
For more details about the TS200 PLC incinerator or to discuss project-specific needs in South Sudan, please visit:
www.hiclover.com
Email: sales@hiclover.com
-
South Sudan incinerator
-
medical waste incinerator for Africa
-
containerized incinerator South Sudan
-
high capacity incinerator TS200 PLC
-
PLC automatic incinerator
-
HICLOVER waste management solutions
Incinérateur de déchets médicaux au Bénin
Incinérateur de déchets médicaux au Bénin : une solution conforme aux normes CE, à haute capacité et adaptée aux besoins locaux
HICLOVER, spécialiste international reconnu dans la fabrication et l’exportation d’incinérateurs de déchets médicaux, présente son modèle spécifiquement configuré pour répondre à un récent appel d’offres au Bénin. Cette solution associe performance environnementale, robustesse et technologie moderne, tout en respectant les exigences strictes des normes CE ou FDA.
Caractéristiques techniques détaillées
Chambre de combustion principale
-
Parois intérieures entièrement isolées avec des matériaux réfractaires de haute qualité, garantissant une excellente rétention thermique et une grande durabilité.
-
Dimensions internes adaptées aux besoins locaux : 1060 x 800 x 700 mm (+/- 5%) pour optimiser la capacité et l’ergonomie de chargement.
-
Capacité de chargement minimale : 200 kg, permettant le traitement efficace des déchets hospitaliers et biologiques.
-
Puissance calorifique : jusqu’à 420 kW (au lieu de 390 kW), offrant une montée en température plus rapide et une meilleure efficacité de destruction.
-
Principe de chauffage à double passage, pour améliorer le rendement thermique et réduire la consommation de carburant.
Chambre de post-combustion (afterburner)
-
Entièrement isolée, fabriquée avec des briques réfractaires spéciales et une isolation à faible masse thermique.
-
Température minimale garantie : 1100°C, assurant une destruction totale des fumées et des polluants.
-
Contrôle automatique par ventilateurs de combustion pilotés et allumage on-off selon la température.
Commande et sécurité
-
Automate programmable (PLC) pour gérer tous les cycles, la sécurité et la maintenance préventive.
-
Écran tactile de 6 pouces pour un pilotage intuitif.
-
Enregistrement automatique des données et export via clé USB, permettant la traçabilité et la conformité réglementaire.
-
Bouton d’arrêt d’urgence et indicateurs de cycle, de fonctionnement et d’anomalie pour garantir la sécurité des opérateurs.
Alimentation et consommation
-
Alimentation électrique : 220–250 V, 50/60 Hz.
-
Carburant : Diesel avec réservoir intégré de 500 litres.
-
Vitesse de combustion : 50–75 kg/h, adaptée aux besoins quotidiens d’un hôpital, d’un centre de santé ou d’un laboratoire.
-
Panneaux isolants de 50 mm superwool pour réduire la déperdition thermique et augmenter la sécurité externe.
-
Conception avec cheminée de section adaptée pour assurer un tirage optimal et limiter les émissions.
Une solution pensée pour l’Afrique de l’Ouest
Cet incinérateur s’inscrit pleinement dans les politiques publiques visant à :
-
améliorer la gestion des déchets hospitaliers,
-
limiter les risques sanitaires,
-
et respecter les normes internationales en matière d’émissions polluantes.
HICLOVER, fort de son expérience auprès des hôpitaux, ONG et organismes internationaux (ONU, OMS, etc.), propose des solutions clé en main : formation des opérateurs, mise en service et assistance technique.
Contact et informations
Pour en savoir plus ou demander un devis personnalisé pour votre établissement au Bénin ou ailleurs en Afrique :
Site web : www.hiclover.com
E-mail : sales@hiclover.com
Mots-clés SEO inclus
incinérateur de déchets médicaux Bénin, incinérateur conforme CE, gestion déchets hospitaliers Afrique, destruction déchets biomédicaux, incinérateur programmable PLC, afterburner haute température.
Small Medical Waste Incinerators in Rwanda
Small Medical Waste Incinerators in Rwanda
Rwanda, known for its rapid economic transformation and commitment to environmental sustainability, has made significant progress in modernizing its healthcare waste management system. With a growing network of district hospitals, health centers, and specialized clinics, the demand for compact, reliable medical waste incinerators has never been greater.
Market Overview: Rwanda’s Healthcare Waste Needs
Rwanda’s healthcare system includes:
-
Over 40 district hospitals
-
Nearly 500 health centers and posts
-
Expanding private clinics in Kigali and secondary cities
These facilities collectively generate a mix of:
-
Sharps (needles, syringes)
-
Infectious dressings and PPE
-
Small quantities of anatomical and pharmaceutical waste
Given Rwanda’s strong environmental policy, there is a national push for:
-
Replacing open burning pits and outdated single-chamber brick incinerators
-
Using dual-chamber incinerators that meet WHO guidelines
-
Introducing small-capacity, energy-efficient units for district-level use
Recent Tenders and Public Procurement
Over the last five years, Rwanda’s Ministry of Health and partner agencies have issued tenders for small medical incinerators. Examples include:
-
Ministry of Health tenders (2019–2023): for “medical waste incinerators, capacity 20–50 kg/hour” targeted at district hospitals and new health posts.
-
Rwanda Biomedical Center (RBC): procurement projects supported by international donors such as the Global Fund, WHO, and the World Bank.
-
Specific projects to support:
-
Maternal and child health hospitals
-
HIV/AIDS and TB care facilities
-
Vaccination campaign sites needing safe sharps disposal
-
Technical requirements typically requested:
-
Dual-chamber combustion
-
Primary combustion chamber ≥ 800°C
-
Secondary chamber ≥ 850°C, minimum 2 seconds residence time
-
Automatic temperature control and digital monitoring
-
Diesel burner (Italy or equivalent) with optional hybrid electric control
-
Chimney height ≥ 8–10 meters
-
Compact footprint suitable for limited urban space
Why the HICLOVER TS30 PLC Fits Rwanda’s Market
The HICLOVER TS30 PLC is specifically designed for small healthcare facilities and district hospitals:
-
Capacity: ~30 kg/hour, matching typical daily waste volumes in district hospitals and private clinics.
-
Dual-chamber design: Achieves complete destruction of pathogens and reduces emissions.
-
Automatic Italy-brand diesel burner controlled by PLC system for stable combustion.
-
PLC (Programmable Logic Controller):
-
Monitors temperature in both chambers
-
Enables safe, hands-free operation
-
Supports operator training and ensures consistent performance
-
Compact installation:
Ideal for hospitals with limited space, as often seen in urban areas like Kigali, Huye, and Musanze.
Fuel efficiency:
Optimized burner design reduces diesel consumption, lowering operational costs—an important consideration for facilities with limited budgets.
Promoting HICLOVER TS30 PLC in Rwanda
With Rwanda’s emphasis on:
-
Infection control
-
Environmental standards aligned with WHO and Basel Convention guidelines
-
Improving rural healthcare services
the HICLOVER TS30 PLC provides:
Small-capacity, locally appropriate solution
Durable design for challenging field conditions
Digital temperature monitoring for regulatory compliance
Affordable installation and after-sales support
HICLOVER’s existing installations across Africa, including similar projects in Uganda, Kenya, and Burundi, demonstrate its capability to supply, train, and maintain small medical incinerators for rural and district-level use.
Environmental and Public Health Benefits
Replacing open burning and older brick incinerators with modern units like the TS30 PLC helps Rwanda achieve:
-
Higher combustion temperatures, reducing harmful pathogens and dioxins
-
Minimal visible smoke and odor, improving community relations
-
Lower residual ash volumes, simplifying disposal
As Rwanda continues to modernize its healthcare infrastructure, there is a clear and growing market for small, dual-chamber medical waste incinerators.
The HICLOVER TS30 PLC, with its robust design and PLC-controlled combustion system, is an ideal solution for district hospitals and clinics seeking to comply with national and international standards.
For technical details, case studies, or a quote tailored for Rwandan healthcare facilities, please visit:
www.hiclover.com
sales@hiclover.com
HICLOVER – delivering efficient, high-temperature incinerators for safer healthcare waste management across Africa.